GX-3R Multigas Detector

The GX-3R is the worlds smallest 4 gas monitor weighing only 3.52 ounces and can comfortably be clipped within a worker’s breathing zone (2.2” W x 2.55” H x 1.02” D). It simultaneously monitors and displays LEL combustibles, O2, CO (Hydrogen compensated CO also available), and H2S.

Thank you for reading this post, don't forget to subscribe!

Portable Multi Gas Detector Configurations

  •  4 gas, LEL / O2 / H2S / CO • 3 gas, LEL / O2 / H2S • 3 gas, LEL / O2 / CO
  • 2 gas, LEL / O2 • 2 gas, O2 / H2S • 2 gas, O2 / CO
  • Single gas LEL, O2, CO, H2S

Application

  • Personal monitoring
  • Confined spaces
  • Refineries/petrochemical
  • Utilities
  • Hazardous material
  • Water/wastewater
  • Fire services
  • Construction

 

Specifications

Gas Detected(CO)
H2 Compensated
Carbon Monoxide(CO)Hydrogen Sulfide(H2S)H2S
Only
Combustible Gases
(Methane as standard)
Oxygen
Dual Sensor
Sensor Slot123
Detection
Principle
ECDual ECECCatalytic combustionEC
Detection Range
(Increments)
0 ~ 2,000 ppm
(1 ppm)
0 ~ 200.0 ppm
(0.1 ppm)
0 ~ 100% LEL
(1% LEL)
0 ~ 40% Vol. (0.1%)
Accuracy
Statement
± 5% of reading
or ± 2 ppm CO
± 5% of reading
or ± 5 ppm CO
(whichever is greater)
± 5% of reading
or ± 2 ppm H2S
(whichever is greater)
± 5% of reading
or ± 2% LEL
(whichever is greater)
± 0.5% of reading O2
Sampling MethodDiffusion sampling standard (hand aspirator or clip-on motorized pump optional)
DisplayDigital LCD displays with 7 segment plus 14 segment plus icon
Preset Alarms
(User Adjustable)
Overscale alarm
(Non-adjustable)
1st alarm: 25.0 ppm
2nd alarm: 50.0 ppm
3rd alarm: 1200.0 ppm
TWA alarm: 25.0 ppm
STEL alarm: 200.0 ppm
Over alarm: 2000.0 ppm
1st alarm: 5.0 ppm
2nd alarm: 30.0 ppm
3rd alarm: 100.0 ppm
TWA alarm: 1.0 ppm
STEL alarm: 5.0 ppm
Over alarm: 200.0 ppm
1st alarm: 10% LEL
2nd alarm: 25% LEL
3rd alarm: 50% LEL
Over alarm: 100% LEL
     
Types of AlarmsGas Alarm: 3 Increasing alarms, STEL, TWA, overscale alarm. O2 decreasing/increasing.
Trouble alarm: Sensor disconnection, low battery, circuit error, calibration range error
Display of AlarmGas Alarm: Flashing LEDs, continuous buzzer (100 db @ 30 cm), flashing gas value, vibration
Trouble alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), display of error message
Operating Temp.
& Humidity
-20°C ~ +50°C [ -4°F ~ +122°F ], 10 to 90% RH, non-condensing (continuous environment)
-40°C ~ +60°C [ -40°F ~ +140°F ], 0 to 95% RH, non-condensing (temporary environment, 15 minutes)
Response TimeWithin 30 seconds (T90)
Power SourceLithium-ion battery, Approx. 25 hours after a 3 hour full charge
Approvals ATEX,  CSA, IECEx, MED
Dimension
& Weight
2.2” W x 2.55” H x 1.02” D (Approx. 58 W x 65 H x 26 D mm), 3.52 ounces (approx. 100 g) without rubber booth
2.4” W x 2.63” H x 1.06” D (Approx. 61 W x 67 H x 27 D mm), 3.70 ounces (approx. 105 g) with rubber booth
Case MaterialDust and water resistant to IP-66/68 (2m,1h) approval. Drop height 23 ft
ControlsTwo buttons: POWER / MODE, AIR
DataloggingLogs user ID, station ID, Calibration & Bump Test history, Alarm Events & Alarm Interval Trends
Standard
Accessories
Alligator clip, protective rubber boot, charger, and calibration adapter
Optional
Accessories
SDM-3R calibration station
RP-3R Clip-on sampling pump with 4” rubber nipple, 10’ hose and probe (up to 40’ hose available)
Padded carrying case for GX-3R and accessories
USB to IrDA downloading cable for datalogger
WarrantyThree years material and workmanship