Tanktech UTI Meter
Restricted Type Portable Oil / Water Interface Detector for Ullage, oil / water interface & temperature gauging
Thank you for reading this post, don't forget to subscribe!SPECIFICATION
MODEL: T2000-TFS-01
Accuracy of ullage, interface detection | + / – 2 mm |
Indication of level divided by ullage and interface | Visible and Audible |
Tape length | 15 M / 30 M/ 40 M |
Tape graduation | Metric |
Tape resolution | 1 mm |
Tape accuracy | +1 – 3.2 mm |
Diameter of probe | 23 mm |
Minimum detectable level | 10 mm |
Ambient temperature range | -20° C to 70° C |
Temperature sensor measurement range | -20° C to 110° C |
Temperature measurement resolution | 0.1° C |
Accuracy over calibration range | +1-0.2° C (0° C to 70° C |
Temperature reading mode | °C(Celsius) |
LCD display | 2 Line 16 character |
Top Coupling (Connection) | PF 2-1/4″ TAP |
Weight | 4.3 kg |
Overall dimensions (H X W X T) | 645 X 315 X 150 mm |
Battery | 9 Volt ( Model : MN1604) |
Intrinsically sate type | Ex ia IIB T4 |
MATERIAL Body : Aluminum plate (JIS – 6061)
COATING In/Out : Epoxy nylon coating
Color : Black
Thickness : (In / Out Side ) 50mic.