VAF ODME System OILCON MK6M
PRODUCT SPECIFICATIONS: VAF Instruments Oilcon Mark 6M, Oil Discharge Monitoring and Control system in accordance with IMO resolution MEPC.108(49), Regulation 31 Annex I of Marpol 73/78 (2011 consolidates edition)
MEPC108(49) as amended by IMO resolution MEPC.240(65).
- Ex proof classification according to:
Ex II(1)G [Ex ia] IIB (interface)
Ex II 1 G Ex ia IIB T4 (detector cell) - Consisting of:
1 off Main Control Unit 24 VDC
1 off Electro Pneumatic Unit, 230 Vac, 50/60Hz, suitable for maximum
2 sample valves, with built-in safety barrier for one flow meter
1 off Air Supply Unit
1 off Air Supply Unit Window Wash Pump
1 off Skid assembly with 15 mm pipe couplings
1 off Isolating valve
1 off Coupling with injection point
1 off Coupling with grab cock
1 off Sample pump /bulkhead gland with 15 mm pipe couplings
1 off Welding-ring for easy mounting of new Sample Point
1 off Gasket
1 off Starter box for Sample Pump
1 off Sample valve assembly with 15 mm pipe couplings
1 off Sample probe with 15 mm pipe coupling, material: 316SS
1*) off Flowmeter(DP/I transmitter) with bracket and manifold for
maximum dp range lower than1000 mbar
2*) off Ball valves
1*) off Orifice Plate: Size to be advised based on info overboard line and flow rate.
1 off Fresh water pressure reducing valve
1 off 10 m cable IC02 for connection EPU to Skid
1 off Box containing the following spare part kit:
1 Sample pump lubricant 500 ml
2 O-rings ID 53.70×1.78mm
2 Fuses 630 mA
1 Cleansing brush - Standard cable connections:
Cable EPU to MCU: M20x1.5 cable diameter 6-12mm
Cable EPU to Skid: M20x1.5 cable diameter 10-14mm
Cable EPU to starterbox: M20x1.5 cable diameter 6-12mm
Cable EPU to Dp/I tx: Pg 13,5Ex cable diameter 6-12mm
Cable EPU to power supply: M20x1.5 cable diameter 6-12mm - Paint: Munsell 7,5 BG 7/2 (standard)
The VAF Oilcon ODME system complies to the latest regulations regarding
the carriage of Biodiesel according to IMO resolution MEPC.108(49), regulation
31 Annex I of Marpol 73/78 (2011 consolidates edition) MEPC108(49) as amended
by IMO resolution MEPC.240(65).
The OILCON MK6M has a DNV type approval, please go to www.sikama.se.
For more Technical details on the new MK6M, please go to www.sikama.se.